Programming Manual
4.7.5 Source – Mode subsystem
[:SOURce]
:MODE CVOLtage | CCURrent | CPOWer
[SOURce:]MODE
This command is used to set or query the power supply's operating mode. The power supply
can operate in either Constant Voltage or Constant Current mode. A <CRD> string is returned
for a MODE? Query as shown in the table below:
<CRD> Mode
CVOL Constant Voltage (CV)
CCUR Constant Current (CC)
CPOW Constant Power (CP)
Table 4-1: Mode query results
Command Syntax [SOURce:]MODE <CRD>
Parameters CVOLtage | CCURrent | CPOWer
Example: MODE CVOL
Query Syntax MODE?
Returned Parameters <CRD>
Related Commands VOLT:PROT:DEL
4.7.6 Source – Power subsystem
[:SOURce]
:POWer
[SOURce:]POWer
This command is used to set or query the constant power mode level. This command is only
relevant if the MODE is set to constant power mode. In the CC or CV modes, this setting has no
effect. The power level set cannot exceed the power level of a single KDC unit, either 5000,
10000 or 15000 depending on model configuration. Also make sure the voltage and current
settings are consistent with the desired power level in CP mode.
Command Syntax [SOURce:]POWer <NRf>
Parameters <NRf>
Example: POW 3400
Query Syntax POW?
Returned Parameters <NR2>
Related Commands VOLT:MODE
56 KDC Series DC Power Supplies