Argantix KDC 80-62 Manuel d'utilisateur Page 55

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 120
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 54
Programming Manual
Command Syntax [SOURce:]LIST:STEP<step>
Parameters ONCE | AUTO
*RST Value AUTO
Examples LIST:STEP ONCE
Query Syntax [SOURce:]LIST:STEP?
Returned Parameters <CRD>
Related Commands LIST:COUN LIST:DWEL
LIST:TTLTrg[:SWITch]
This command sets the sequence of Trigger Out list points. Each point set to “1” will cause a
pulse to be output at Trigger Out (Function strobe) output when that list step is reached. Those
entries which are set “0” will not generate Trigger Out pulses. The order in which the list points
are given determines the sequence in which Trigger Out pulses will be output when a list
transient is triggered.
Command Syntax [SOURce:]LIST:TTLTrg[:SWITch] <bool> ,<bool>
Parameters 0 | 1 | OFF | ON
Examples LIST:TTLT 1,0,1 LIST:TTLT ON,OFF,ON
Query Syntax LIST:TTLT?
Returned Parameters 0 | 1
Related Commands LIST:TTLT:POIN? LIST:COUN LIST:DWEL
LIST:STEP OUTP:TTLT:STAT OUTP:TTLT:SOUR
LIST:TTLTrg:POINts?
This query returns the number of points specified in LIST:TTLT. Note that it returns only the total
number of points, not the point values.
Query Syntax [SOURce:]LIST:TTLTrg:POINts?
Returned Parameters <NR1>
Example LIST:TTLT:POIN?
Related Commands LIST:TTLT
LIST:VOLTage[:LEVel][:AMPLitude]
This command specifies the output voltage points in a list. The voltage points are given in the
command parameters, which are separated by commas. The order in which the points are
entered determines the sequence in which the list will be output when a list transient is
triggered.
Command Syntax [SOURce:]LIST:VOLTage[:LEVel][:AMPLitude] <NRf+>,<NRf+>
Parameters 0 to MAX
Unit Volt
Examples LIST:VOLT 2.0,2.5,3.0
Query Syntax [SOURce:]LIST:VOLTage[:LEVel]?
Returned Parameters <NR2>
Related Commands LIST:VOLT:POIN? LIST:COUN LIST:DWELLIST:STEP
LIST:VOLTage[:LEVel]:POINts?
This query returns the number of points specified in LIST:VOLT. Note that it returns only the
total number of points, not the point values.
54 KDC Series DC Power Supplies
Vue de la page 54
1 2 ... 50 51 52 53 54 55 56 57 58 59 60 ... 119 120

Commentaires sur ces manuels

Pas de commentaire