Programming Manual
5.7.1 Voltage, Current and Power Measurements
To the rms voltage or current, use:
MEASure:VOLTage?or
MEASure:CURRent?
To measure the maximum current amplitude, use:
MEASure:CURRent:AMPLitude:MAXimum?
To reset the peak measurement , use
MEAS:CURR:AMPL:RESet
To measure the power, use:
MEASure:POWer?
5.7.2 Returning Voltage and Current Data From the Data Buffer
The MEASure and FETCh queries can also return all 4096 data values of the instantaneous
voltage and current buffers. These are:
MEASure:ARRay:CURRent[:DC]?;*WAI
MEASure:ARRay:VOLTage[:DC]?;*WAI
5.7.3 Triggering Measurements
You can use the data acquisition trigger system to synchronize the timing of the voltage and
current data acquisition with an external trigger source. Then use the FETCh commands to
return different calculations from the data acquired by the measurement trigger.
The following measurement trigger sources can be selected:
IMMediate Aquire the measurements immediate
BUS IEEE-488 device, *TRG, or <GET> (Group Execute Trigger)
TTLTrg The signal driving the Trigger Out
5.7.4 Measurement Trigger System Model
Figure 5-2 is a model of the measurement trigger system. The rectangular boxes represent
states. The arrows show the transitions between states. These are labeled with the input or
event that causes the transition to occur.