Programming Manual
CALibrate:MEASure:VOLTage[:AMBient][:FSCale] <NRf>
This command initiates the calibration of the DC voltage measurement at full scale and at
ambient temperature.
Command Syntax CALibrate:MEASure:VOLTage[:AMBient][:FSCale]
Parameters <NRf> (actual DC output voltage measured with external device)
Examples CAL:MEAS:VOLT 120
Query Syntax CALibrate:MEASure:VOLTage?
Returned Parameters <NRf>
Related Commands CALibrate:MEASure:VOLTage:ZERO
CALibrate:MEASure:VOLTage[:AMBient]:ZERO <NRf>
This command initiates the offset adjustment of the DC voltage measurement at ambient
temperature.
Command Syntax CALibrate:MEASure:VOLTage[:AMBient]:ZERO
Parameters <NRf> (0 or desired offset value)
Examples CAL:MEAS:VOLT:ZERO 0
Query Syntax CALibrate:MEASure:VOLT:ZERO?
Returned Parameters <NRf>
Related Commands CALibrate:MEASure:VOLTage[:AMBient][:FSCale]
CALibrate:MEASure:VOLTage:TEMPerature[:FSCale] <NRf>
This command initiates the calibration of the DC voltage measurement at full scale and at
elevated temperature.
Command Syntax CALibrate:MEASure:VOLTage:TEMPerature[:FSCale]
Parameters <NRf> (actual DC output voltage measured with external device)
Examples CAL:MEAS:VOLT:TEMP 120
Query Syntax CALibrate:MEASure:VOLTage:TEMPerature?
Returned Parameters <NRf>
Related Commands CALibrate:MEASure:VOLTage[:AMBient][:FSCale]
28 KDC Series DC Power Supplies