Programming Manual
4.7.3 Source - Limit subsystem
[:SOURce]
:LIMit
:CURRent? Current range limit: Model specific
:VOLTage? Voltage range limit. Model specific
The Source Limit sub-system may be used to query the maximum capabilities of the DC Supply.
LIMit:CURRent
This command will return the maximum current the power supply can deliver to the load. Only
the query format of this command is available.
Command Syntax [SOURce:]LIMit:CURRent <NRf> [command protected]
Parameters maximum current
Example: LIM:VOLT?
Query Syntax [SOURce:]LIMit:CURRent?
Returned Parameters <NR2>
Related Commands LIM:VOLT?
LIMit:VOLTage
This command will return the maximum voltage of the power supply. Only the query format of
this command is available.
Command Syntax [SOURce:]LIMit:VOLTage <NRf> [command protected]
Parameters voltage range]
Example: LIM:VOLT?
Query Syntax [SOURce:]LIMit:VOLTage?
Returned Parameters <NR2>
Related Commands LIM:CURR?
50 KDC Series DC Power Supplies