Programming Manual
Command Syntax SYSTem:COMMunicate:SERial:BITS <NRF>
Parameters 7|8
Example SYST:COMM:SER:BITS 8
Returned Parameters <NR1>
SYSTem:COMMunicate:SERial:SBITs
This command will set the SERial communication number of stop bits.
Command Syntax SYSTem:COMMunicate:SERial:SBITs <NRF>
Parameters 1|2
Example SYST:COMM:SER:SBITs 1
Returned Parameters <NR1>
SYSTem:CONFigure[:BYTE]
This command will set the system configuration. This is a protected command and requires a
password. The query format is available however. Refer to the *OPT? Command for system
options.
Command Syntax SYSTem:CONFigure[:BYTE]
Parameters SCPI, DO160,MIL704, FT
Example SYST:CONF SCPI SYST:CONF?
Returned Parameters <CRD>
Related Commands *OPT?
SYSTem:ERRor?
This query returns the next error number followed by its corresponding error message string
from the remote programming error queue. The queue is a FIFO (first-in, first-out) buffer that
stores errors as they occur. As it is read, each error is removed from the queue. When all errors
have been read, the query returns 0,”No Error”. If more errors are accumulated than the queue
can hold, the last error in the queue is -350,”Queue overflow”.
Query Syntax SYSTem:ERRor?
Parameters None
Returned Parameters <NR1>,<SRD>
Example SYST:ERR?
SYSTem:ETIMe?
This command will return the total number of accumulated hours, minutes and seconds.
Command Syntax SYSTem:ETIMe?
Parameters none
Example SYST:ETIM?
Returned Parameters <NR1>,<NR1>,<NR1>
SYSTem:LOCal
This command sets the interface in Local state, which enables the front panel controls. This
command only applies to the RS232C interface. If IEEE 488 is used, the remote/local state is
determined by the REN line on the IEEE 488 interface. In GPIB model, the SYST:LOC and
SYST:REM commands will not be accepted and will generate an error message.
KDC Series DC Power Supplies 71