Argantix KDC 80-62 Manuel d'utilisateur Page 104

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 120
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 103
Programming Manual
:MIL704:SSTate:VOLTage:RIPPle
This command initiates the Steady state voltage ripple test step.
Command Syntax :MIL704:SSTate:VOLTage:RIPPle
Parameters none
Examples :MIL704:SST:RIPP
Query Syntax n/a
Returned Parameters n/a
Related Commands :MIL704:SSTate:VOLTage
:MIL704:TRANsient:VOLTage[:LOW]
This command initiates the Transient low voltage level test step.
Command Syntax :MIL704:TRANsient:VOLTage[:LOW]
Parameters none
Examples :MIL704:TRAN:VOLT
Query Syntax n/a
Returned Parameters n/a
Related Commands :MIL704:TRANsient:VOLTage:HIGH
:MIL704:TRANsient:VOLTage:HIGH
This command initiates the Transient high voltage level test step.
Command Syntax :MIL704:TRANsient:VOLTage:HIGH
Parameters none
Examples :MIL704:TRAN:VOLT:HIGH
Query Syntax n/a
Returned Parameters n/a
Related Commands :MIL704:TRANsient:VOLTage:LOW
:MIL704:ABNormal:VOLTage[:UNDer]
This command initiates the Abnormal under-voltage level test step.
Command Syntax :MIL704:ABNormal:VOLTage[:UNDer]]
Parameters none
Examples :MIL704:ABN:VOLT
Query Syntax n/a
Returned Parameters n/a
Related Commands :MIL704:ABNormal:VOLTage:OVER
:MIL704:ABNormal:VOLTage:OVER
This command initiates the Abnormal over-voltage level test step.
Command Syntax :MIL704:ABNormal:VOLTage:OVER
Parameters none
Examples :MIL704:ABN:VOLT:OVER
Query Syntax n/a
Returned Parameters n/a
Related Commands :MIL704:ABNormal:VOLTage:UNDer
KDC Series DC Power Supplies 103
Vue de la page 103
1 2 ... 99 100 101 102 103 104 105 106 107 108 109 ... 119 120