Programming Manual
4.5 Output Subsystem
This subsystem controls the main outputs, the signal outputs and the output impedance of the
DC supply.
Subsystem Syntax
OUTPut
:IMPedance
[:STATe] Enable/disable output impedance program
:REAL Sets resistive part of output impedance
RI[:LEVel] Sets Remote Inhibit input level mode (LOW | HIGH).
[:STATe] Enable/disable output voltage, current, power, etc.
:TTLTrg
[:STATe] Enable/disable trigger out drive
:SOURce Selects a TTLTrg source (BOT|EOT|LIST)
OUTPut:IMPedance[:STATe]
This command enables or disables the supply's output impedance programming. The state of a
disabled output impedance is equivalent to the minimum impedance. The query form returns the
output state.
Command Syntax OUTPut:IMPdance[:STATe]<bool>
Parameters 0 | OFF | 1 | ON
*RST Value OFF
Examples OUTP:IMP 1 OUTP:IMP:STAT ON
Query Syntax OUTPut:IMPdeance[:STATe]?
Returned Parameters 0 | 1
Related Commands OUTPut:IMPedance:REAL
OUTPut:IMPedance:REAL
This command sets the real part of the output impedance of the AC source in mili-ohms.
OUTPut:IMPedance:STATe must be enabled for the programmed impedance to affect the
output. The available range is a function of voltage and current range of the DC supply and can
be queried using the "OUTP:IMP:REAL? MIN" and "OUTP:IMP:REAL? MAX" commands
Command Syntax OUTP:IMPedance:REAL<NRf>
Parameters model specific.
*RST Value min
Examples OUTP:IMP:REAL 20
Query Syntax OUTPut:IMP:REAL?
Returned Parameters <NR2>
Related Commands OUTP:IMP
KDC Series DC Power Supplies 41