Programming Manual
2.6 Trouble Shooting - IEEE-488 / GPIB
This section provides guidelines for resolving communication problems that may occur when
using the KDC series with or without the KDCGUI software with a IEEE-488 / GPIB interface.
Symptoms:
1. Unable to verify connection to the power supply through IEEE-488 interface. Time-out
occurs any time an attempt is made to verify connection.
Things to check:
1. Is the interface option set to use the IEEE-488 interface instead of the RS232C interface?
2. Does the bus address selected in the configuration menu of the KDC supply match the
address selected in the System, Interface dialog windows?
3. Did you connect the cable in correctly and are both ends of the GPIB cable securely tied
down?