Programming Manual
4.3 Initiate Subsystem
This subsystem controls the triggering of the DC power supply. See section 5.6 under
"Triggering Output Changes" for an explanation of the Trigger Subsystem. The INITiate
commands control the initialization of the transient system. The trigger subsystem must first be
enabled using the INITiate commands or no triggering action will occur. Refer to Figure 5-1 for a
block diagram of the trigger system.
Subsystem Syntax
INITiate
[:IMMediate] Initiates the system for one trigger
[:TRANsient]
:ACQuire
:CONTinuous sets if the initate continuous to (ON|OFF)
INITiate[:IMMediate][:TRANsient]
The INITiate command controls the initiation of the transient generation or measurement
acquisition trigger system. They cause the trigger system to make a transition from the Idle state
to the Waiting-for-Trigger state. If the trigger system is not in the Idle state, the initiate
commands are ignored.
If both the transient generation and the measurement acquisition trigger systems are initiated at
the same time, the first trigger event that occurs will trigger the measurement system. The
transient system will trigger on the next trigger event. Thus, the measurement system has a
higher trigger priority than the the transient system. If the measurement trigger is generated by a
transient event, the acquisition system should be initiated first so it is waiting for the trigger
caused by the transient system.
Command Syntax INITiate[:IMMediate][:TRANsient
Parameters None
Examples INIT
Related Commands ABOR INIT:CONT *TRIG
INITiate:ACQuire
The INITiate:ACQuire command controls the initiation of the measurements trigger system. They
cause the trigger system to make a measurement from the Idle state to the Waiting-for-Trigger
state. If the trigger system is not in the Idle state, the initiate commands are ignored.
Command Syntax INITiate:ACQuire
Parameters None
Examples INIT:ACQ
Related Commands ABOR INIT:CONT *TRIG
INITiate:CONTinuous
These commands control the transient generator trigger system.
 1 or ON continuously initiates the transient trigger system.
 0 or OFF turns off continuous triggering. In this state, the trigger system must be initiated for
each triggered event using INITiate:TRANsient.
KDC Series DC Power Supplies 33