Programming Manual
7.2 Mil-Std 704 Option -704
MIL704 tests can be executed remotely from the GPIB or RS232 using the following command
tree. See the KDC Series User Manual (P/N 5005-960) for more details about each 704 test
step.
7.2.1 DC System
:MIL704
:VERSion D|E
:SSTate
:VOLT
[:LEVel]
:RIPPle
:TRANsient
:VOLTage
[:LOW]
:HIGH
:ABNormal
:VOLTage
[:UNDer]
:OVER
:EMERgency
:VOLTage
Note that none of these commands accept parameters nor have a query format except for the
MIL704:VERSion command, which accepts a letter D or E as a parameter. Its query format
response will return the letter D or E based on the revision selected.
:MIL704:VERSion
This command sets the Mil Std 704 standard revision to be used. Available versions are D and
E. Older and or newer versions may be added through firmware updates. Note that this is the
only MIL704 command that has a parameter and supports the query format.
Command Syntax :MIL704:VERSion
Parameters D | E
*RST Value E
Examples :MIL704:VERS D
Query Syntax :MIL704:VERSion?
Returned Parameters <CRD>
Related Commands none
:MIL704:SSTate:VOLTage[:LEVel]
This command initiates the Steady state voltage level test step.
Command Syntax :MIL704:SSTate:VOLTage[:LEVel]
Parameters none
Examples :MIL704:SST:VOLT
Query Syntax n/a
Returned Parameters n/a
Related Commands :MIL704:SSTate:VOLTage:RIPPle
102 KDC Series DC Power Supplies
Vue de la page 102