Programming Manual
:CONDition Returns the value of the condition register
:ENABle Enables specific bits in the Event register
:EVENt Returns the value of the event register
:INSTrument
:ISUMmary
:CONDition Returns the selected phase’s condition register
:ENABle Enable specific bits in selected phase’s Event register values
:EVENt Returns the selected phase’s event register value
SYSTem:
COMMunicate: Communication settings
GPIB:ADDRess GPIB address, 1 to 31
SERial:
BUAD 9600 | 19200 | 38400 | 57600 | 115200
PARity NONE | EVEN | ODD
BITS 7 | 8
SBITS 1 | 2
CONFigure:
[:BYTE] System configuration query
ERRor? Returns the error number and error string
ETIMe? Elapsed Time query
LOCal Go to local mode
PON Define the power on register number
REMote Go to remote mode
RWLock Local Lockout
TEMPerature Controller temperature query or error state.
VERSion IEEE488.2 version
TRIGger
:ACQuire
[:IMMediate Initiate data acquisition
:SOURce Set the acquire trigger source
:STATe? Return the trigger state (IDLE | WTRIG | BUSY)
[:TRANsient]
[:IMMediate] Initiate transient
:SOURce Sets the trigger source (IMMediate | BUS | EXTernal)
108 KDC Series DC Power Supplies