Programming Manual
Command Syntax SYSTem:LOCal
Parameters None
Example SYST:LOC
Related Commands SYST:REM
SYSTem:PON
This command is used to define the register value (0 though 7) the power supply will use to
initialize its parameters at power up. If data in the selected register is not valid or the selected
register is 8, the initialization will be with factory default values.
Command Syntax SYSTem:PON <NRf>
Parameters 0 to 8
Examples SYST:PON 1
Query Syntax SYST:PON?
Returned Parameters <NR1>
Related Commands *RST *SAV
SYSTem:REMote
This command sets the interface in the Remote state, which disables all front panel controls.
This command only applies to the RS232C interface. If IEEE 488 is used, the remote/local
status is determined by the REN line on the IEEE 488 interface. In GPIB model, the SYST:LOC
and SYST:REM commands will not be accepted and will generate an error message.
Command Syntax SYSTem:REMote
Parameters None
Example SYST:REM
Related Commands SYST:LOC SYST:RWL
SYSTem:TEMPerature
The query format of this command will return the internal ambient temperature of the DC power
supply in degrees Celsius. The non-query mode can be used to disable Error 21. If Error 21 is
disabled, the output will not trip when the maximum allowable ambient temperature is exceeded.
This could result in intermittent controller errors however if the ambient temperature ratings are
exceeded and is not recommended. Factory setting is fault 21 enabled. Once the state for Error
21 is set, it is retained at power up.
The trip point is set to 55° C as measured by the KDC controller. The operating range maximum
is 40° C. Note that the non-query format is only supported on units with firmware revision 1.20
or higher.
Command Syntax SYSTem:TEMPerature
Parameters 0 | 1
Example SYST:TEMP?
Returned Parameters <NR2>
SYSTem:RWLock
This command can only be used with the RS-232 interface. It locks out the Local key on the
front panel. The SYST:LOC command must be used to unlock the front panel. For GPIB, use the
Local Lockout bus message.
Command Syntax SYSTem:RWLock
Parameters None
Example SYST:RWL
Related Commands SYST:LOC
72 KDC Series DC Power Supplies