Programming Manual
Command Syntax [SOURce:]VOLTage:REFerence <param>
Parameters INTernal | EXT5V | EXT10V | EXTRES
*RST Value INTernal
Examples VOLT:REF INT VOLT:REF EXT10V
Query Syntax [SOURce:]VOLTage:REF?
Returned Parameters <CRD>
Related Commands CURR:REF VOLT
[SOURce:]VOLTage:SLEW[:IMMediate]
This command sets the voltage slew rate. The voltage slew rate determines the rate of change
when a new voltage level is programmed. The maximum slew rate that can be programmed is a
function of the available voltage range and will differ from model to model. The MAX parameter
may be used to set or query the maximum slew rate.
Command Syntax [SOURce:]VOLTage:SLEW[:IMMediate] <NRf>
Parameters 0 to MAX
*RST Value MAX
Examples VOLT:SLEW 100 VOLT:SLEW MAX
Query Syntax [SOURce:]VOLTage:SLEW? MAX VOLT:SLEW?
Returned Parameters <NR2>
Related Commands VOLT:TRIG VOLT
[SOURce:]VOLTage:SLEW:MODE
This command sets the voltage slew rate programming mode. Available modes are:
FIXed The voltage slew level set is unaffected by a triggered output transient.
STEP The voltage slew level set is programmed to the value set by
VOLTage:SLEW:TRIGgered when a triggered transient occurs.
PULSe The voltage slew level set is changed to the value set by
VOLTage:SLEW:TRIGgered for a duration determined by the pulse commands.
LIST The voltage slew level set is controlled by the voltage slew list when a triggered
transient occurs.
The voltage slew may be set between zero and the model's maximum voltage slew capability
(determined by model) which can be queried with the VOLT:SLEW? MAX command.
Command Syntax [SOURce:]VOLTage:SLEW:MODE <mode>
Parameters FIXed | STEP | PULSe | LIST
*RST Value FIX
Examples VOLT:SLEW:MODE LIST VOLT:MODE FIX
Query Syntax [SOURce:]VOLTage:SLEW:MODE?
Returned Parameters <CRD>
Related Commands VOLT:TRIG VOLT
[SOURce:]VOLTage:SLEW:TRIGgered
This command sets the voltage slew rate trigger level. When triggered by a step or pulse
transient, the voltage slew rate will be set to the programmed level. Note that the new slew rate
does not take effect until the unit is armed and a trigger event occurs. A parameter of MAXimum
will set the slew to its maximum possible rate.
The voltage slew may be set between zero and the model's maximum voltage slew capability
(determined by model) which can be queried with the VOLT:SLEW? MAX command.