Programming Manual
MEASure:ARRay:POWer[:DC]?
FETCh:ARRay:POWer[:DC]?
These queries return an array containing the instantaneous output power in watts. The data
returned in arbitrary block data format as follows:
#5<block length n><b0><b1><b2><b3>.....<bn-3><bn -2><bn-1><bn>
where b0,b1,b2,b3 are four hex bytes represent IEEE single precision floating number, where b0
is the most significant byte and b3 is the least significant byte.
The output voltage, current and power are digitized whenever a measure command is given or
whenever an acquire trigger occurs. The time interval between samples can range from 20.833
microseconds to 208.33 microseconds. The query SENSe:SWEep:TINTerval? will return the
time interval, the position of the trigger relative to the beginning of the data buffer is determined
by SENSe:SWEep:OFFSet.
Query Syntax MEASure:ARRay:POWer[:DC]? [<n>, <n>]
FETCh:ARRay:POWer[:DC]? [<n>, <n>]
Parameters Optional block and offset parameters <n>,<n>. Where the first value
<n> is the number of 256 sample blocks to transfer and the second
value <n> is the first block (offset) to start with. Number of blocks is
from 1 to 16, offset is from 0 to 15.
Examples MEAS:ARR:VOLT? FETC:ARR:VOLT?
Returned Parameters <BNRD> 4096 data points in arbitrary block data format
Related Commands MEAS:ARR:VOLT SENS:SWE
MEASure:ARRay:VOLTage[:DC]?
FETCh:ARRay:VOLTage[:DC]?
These queries return an array containing the instantaneous output voltage in volts. The data
returned in arbitrary block data format as follows:
#5<block length n><b0><b1><b2><b3>.....<bn-3><bn -2><bn-1><bn>
where b0,b1,b2,b3 are four hex bytes represent IEEE single precision floating number, where b0
is the most significant byte and b3 is the least significant byte.
The output voltage, current and power are digitized whenever a measure command is given or
whenever an acquire trigger occurs. The time interval between samples can range from 20.833
microseconds to 208.33 microseconds. The query SENSe:SWEep:TINTerval? will return the
time interval, the position of the trigger relative to the beginning of the data buffer is determined
by SENSe:SWEep:OFFSet.
Query Syntax MEASure:ARRay:VOLTage[:DC]? [<n>, <n>]
FETCh:ARRay:VOLTage[:DC]? [<n>, <n>]
Parameters Optional block and offset parameters <n>,<n>. Where the first value
<n> is the number of 256 sample blocks to transfer and the second
value <n> is the first block (offset) to start with. Number of blocks is
from 1 to 16, offset is from 0 to 15.
Examples MEAS:ARR:VOLT? FETC:ARR:VOLT?
Returned Parameters <BNRD> 4096 data points in arbitrary block data format
Related Commands MEAS:ARR:CURR SENS:SWE
38 KDC Series DC Power Supplies