Programming Manual
:MIL704:EMERgency:VOLTage
This command initiates the Emergency voltage level test step.
Command Syntax :MIL704:EMERgency:VOLTage
Parameters none
Examples :MIL704:EMER:VOLT
Query Syntax n/a
Returned Parameters n/a
Related Commands none
7.2.2 Programming Considerations
Some of the tests take a long time to complete. The *OPC command may be used to determine
the completion of the command.
Example:
MIL704:SST:VOLT;*OPC 1
The query *OPC? Will return a 0 while the test is in progress and a 1 when the test is completed.